MCQ PSYCHROMETRIC CHART

MCQ increases the depth of understanding

and clarity. It clarifies the heating and

humidification, cooling and

dehumidification processes. All other

psychrometric processes on chart is made

understood. All this information is helpful

in the designing of air conditioning

equipment.

  1. Specific humidity is on

    1. Vertical on extreme right

    2. Vertical on extreme left

    3. Both (a) & (b)

    4. None

ANS: (a)

  1. Sensible heat factor is on

    1. Vertical on extreme right

    2. Vertical on extreme left

             © Both (a) & (b)

             (d)None

ANS: (a)

  1. Dry bulb temperature is on

    1. Vertical axis

    2. Horizontal axis

    3. Both (a) & (b)

    4. None

ANS: (b)

  1. Wet bulb temperature is on 100 % R.H. curve where cuts a constant

    1.  Pressure line

    2. Enthalpy line

    3.  Dry bulb temperature line

    4. None

ANS: (b)

  1. Dew point temperature is on 100 % R.H. curve where cuts a

    1. Horizontal line from the given wet bulb temperature

    2. Horizontal line from the given dry bulb temperature

    3. Vertical line from the given specific humidity

    4. None

ANS: (b)

  1. Constant value of Relative Humidity is represented by

    1. Horizontal lines

    2. Vertical lines

    3. Curves

    4. None

ANS: (c )

  1. Relative humidity increases as we move from

    1. Left to right

    2. Right to left

    3. Both (a) & (b)

    4. None

ANS: (b)

  1. Constant enthalpy lines are slant parallel lines which pass through constant

    1.  Dry bulb temperature meeting the 100 % R.H. curve

    2. Wet bulb temperature at 100 % R.H. curve

    3. Both (a) & (b)

    4. None

ANS: (b)

  1. Constant specific volume lines are

    1. Vertical lines

    2. Horizontal lines

    3. Curves

    4. None

ANS: (c )

  1. Specific volume increases as we move from

    1. Left to right

    2. Right to left

    3. Both (a) & (b)

    4. None

ANS: (a)

  1. Constant dry bulb temperature values are represented by

    1. Horizontal lines

    2. Vertical lines

    3. Curves

    4. None

ANS: (b)

  1. Constant wet bulb temperature values are represented by

    1. Horizontal lines

    2. Vertical lines

    3. Curves

    4. None

ANS: (d)

  1. Sensible heating on chart is represented by

    1. Horizontal line from right to left

    2. Horizontal line from left to right

    3. Vertical line

    4. None

ANS: b)

  1. Increase of specific humidity is as we move from

    1. Left to right

    2. Right to left

    3. Vertically upwards

    4. None

ANS: ©

  1. Increase in Sensible Heat Factor is as we move from

    1. Left to right

    2. Vertically upwards

    3. Vertically downwards

    4. None

ANS: (c )

  1. On chart, sensible cooling presented as we move from

    1. Left to right

    2. Right to left

    3. Vertically upwards

    4. None

ANS: (b)

  1. On chart, humidification presented by as we move from

    1. Right to left

    2. Left to right

    3. Vertically downwards

    4. None

ANS: (d)

    18. On chart, dehumidification presented by as we move from

    1. Right to left

    2. Left to right

    3. Vertically downwards

    4. None

ANS: (c)

    19. On chart, humidification and heating presented by as we move from

    1. Right to left

    2. Left to right

    3. Vertically downwards

    4. None

ANS: (d)

  1.     20. Heating & Humidification on chart is represented by as we move in a slant direction from
    1. Right to left

    2. Left to right

    3. Vertically downwards

    4. None

ANS: (b)

    21. Cooling & Humidification on chart is represented by as we move in a slant direction from

    1. Right to left

    2. Left to right

    3. Vertically downwards

    4. None

ANS: (a)

    22. Cooling & Dehumidification on chart is represented by as we move in a slant direction from

    1. Right to left

    2. Left to right

    3. Vertically downwards

    4. None

ANS: (a)

    23. Heating & Dehumidification on chart is represented by as we move in a slant direction from

    1. Right to left

    2. Left to right

    3. Vertically downwards

    4. None

ANS: (b)

    24. On chart, adiabatic saturation presented by a constant

    1.  R. H. curve

    2.  Enthalpy line

    3.  Specific humidity line

    4. None

ANS: (b)